Customized configuration of your mass interconnect interface

Flexible use of the ODU-MAC® modules

YOUR BENEFITS

Easy handling: tool-free clip-in assembly and removal of the modules in the frame

  • Easy mounting and removal of contacts
  • Constantly low contact resistance
  • Customized combination of the different modules
  • High packing density
  • Modules including cable assembly

Signal – 20 contacts

Operating voltage 200 V
Rated surge voltage 2,000 V
Max. continuous current 11 A for 0.14 mm²

Signal 10 contacts

Operating voltage 320 V
Rated surge voltage 2,500 V
Max. continuous current 11 A for 0.14 mm²

Signal – 6 contacts

Operating voltage 400 V
Rated surge voltage 3,000 V
Max. continuous current 19.5 A for 1 mm²

Signal – 5 contacts

Operating voltage 630 V
Rated surge voltage 3,000 V
Max. continuous current 33 A for 2.5 mm²

Signal – 192 contacts

Operating voltage up to 370 V
Test voltage up to 1,588 V
Contact grid 2.54 mm

Signal – 384 contacts

Operating voltage up to 370 V
Test voltage up to 1,588 V
Contact grid 2.54 mm

PCB termination modules – 20 contacts

Operating voltage 200 V
Rated surge voltage 2,000 V
Max. continuous current 7 A

PCB termination modules – 10 contacts

Operating voltage 320 V
Rated surge voltage 2,500 V
Max. continuous current 7 A

PCB termination modules – 6 contacts

Operating voltage 400 V
Rated surge voltage 3,000 V
Max. continuous current 13 A

PCB termination modules – 5 contacts

Operating voltage 550 V
Rated surge voltage 3,000 V
Max. continuous current 25 A

PE module – 1 contact

Conduct cross-section 10 / 16 / 25 mm²

High‐voltage – 2 contacts

Operating voltage 4,000 V
Rated surge voltage 12,000 V

High-current – 3 contacts

Operating voltage 2,500 V
Rated surge voltage 10,000 V
Max. continuous current 58 A for 6 mm²

High‐current – 2 contacts for turned contacts with ODU LAMTAC®

Operating voltage 400 V
Rated surge voltage 4,000 V
Max. continuous current 108 A for 16 mm²

High‐current – 2 contacts for turned contacts with ODU LAMTAC®

Operating voltage 400 V
Rated surge voltage 3,000 V
Max. continuous current 154 A for 25 mm²

High‐current – 1 contact for turned contacts with ODU LAMTAC®

Operating voltage 2,500 V
Rated surge voltage 10,000 V
Max. continuous current 225 A for 50 mm²

Coax – 4 contacts for 50 Ω coax contacts

Frequency range 0–2.8 GHz

Coax – 2 contacts for 50 Ω coax contacts

Frequency range 0–4 GHz

Coax – 2 contacts for 50 Ω coax contacts

Frequency range 0–12 GHz

Coax – 2 contacts for 75 Ω coax contacts

Frequency range 0–2.7 GHz

Compressed air / fluid / vacuum coupling – 2 contacts

Tube-∅ inner-∅: max. 4 mm
Tube-∅ outer-∅ Push-in: max. 6 mm

Compressed air / fluid / vacuum coupling – 2 contacts

Tube-∅ M5 max. 4 mm

Compressed air / fluid / vacuum coupling – 2 contacts

Tube-∅ M5 inside thread

Compressed air / fluid / vacuum coupling – 1 contact

Tube-∅ 16 mm

Shielded feedthrough / high‐speed connector – 2 to 14 contacts for 2 insert size 1

Suitable for all common bus systems CAT 5, USB  2.0, USB  3.2 Gen 1x1, FireWire®, Ethernet, SPE 1000BASE-T1

Mating cycles min. 10,000

Shielded feedthrough / high‐speed connector – 2 to 14 contacts for 1 insert size 1

Suitable for all common bus systems CAT 5, USB  2.0, USB  3.2 Gen 1x1, FireWire®, Ethernet, SPE 1000BASE‐T1

Mating cycles min. 10,000

Shielded feedthrough / high‐speed connector – 3 to 22 contacts for 1 insert size 2

Suitable for all common bus systems CAT 5, CAT 6A, USB® 3.2 Gen 1x2, Ethernet, HDMI® 2.0/2.1, DisplayPort® 2.0

Mating cycles min 10,000

Shielded feedthrough / high‐speed connector – 1 contact

10 gigabit Ethernet according to IEEE 802.3 an CAT 6A according to ANSI/TIA/EIA‐568‐C.2 CAT 6A according to ANSI/TIA‐568.2‐D

Mating cycles min 5,000

Combination module – 2 contacts (High‐speed & coax)

Selected inserts are suitable and qualified for data rates up to 5 Gbit/s. Suitable for CAT 5, USB 2.0, USB 3.2 Gen 1x1, FireWire®, Ethernet, SPE 1000BASE‐T1

Coax 50 Ω/4 GHz or 75 Ω/2.2 GHz

Combination module – 2 contacts (High‐speed & compressed air)

Selected inserts are suitable and qualified for data rates up to 5 Gbit/s. Suitable for CAT 5, USB 2.0, USB 3.2 Gen 1x1, FireWire®, Ethernet, SPE 1000BASE‐T1

Compressed air 12 bar

Fiber optic (on request) – 4 contacts for fiber optic only pre‐assembled (Physical Contact)

Max. insertion loss 0.5 dB
Single mode 9 / 125 μm
Multi mode 50 / 125 μm

Fiber optic (on request) – 4 contacts for fiber optic only pre‐assembled (Expanded Beam)

Max. insertion loss 1.5 dB
Multi mode 50 / 125 μm

Fiber optic – 5 contacts for fiber optic POF

Insertion loss typical 1,5 dB for 670 nm

Blank modules – Used to fill incomplete frames

ODU-MAC® Black-Line Configurator

Use this configurator to request new modules for your existing ODU-MAC® interface.

¹ According to IEC 61010-1:2010 (VDE 0411-1:2020-03), supply voltage from grid supply circuit (Cat.2)

2 Determined according to IEC 60512-5-2:2002 (DIN EN 60512-5-2:2003-01) at increased temperature 45 K

3 Single Pair Ethernet according to IEC 63171-6:2020 (IEEE 802.3bp)