YOUR BENEFITS

Easy handling: tool-free clip-in assembly and removal of the modules in the frame

  • Easy mounting and removal of contacts
  • Constantly low contact resistance
  • Customized combination of the different modules
  • High packing density
  • Modules including cable assembly

Signal – 20 contacts

Operating voltage ¹ 200 V
Test voltage ¹ 1,076 V AC
Nominal current ² 7 A for 0.38 mm²

Signal 10 contacts

Operating voltage ¹ 320 V
Test voltage ¹ 1,320 V AC
Nominal current ² 7 A for 0.38 mm²

Signal – 6 contacts

Operating voltage ¹ 500 V
Test voltage ¹ 1,730 V AC
Nominal current ² 12.5 A for 1 mm²

Signal – 5 contacts

Operating voltage ¹ 672 V
Test voltage ¹ 1,959 V AC
Nominal current ² 24 A for 2.5 mm²

Signal – 192 contacts

Operating voltage ¹ up to 370 V
Test voltage ¹ up to 1,588 V
Nominal current ² 7 A for 0.38 mm²

Signal – 384 contacts

Operating voltage ¹ up to 370 V
Test voltage ¹ up to 1,588 V
Nominal current ² 7 A for 0.38 mm²

PCB termination modules – 20 contacts

Operating voltage ¹ 200 V
Test voltage ¹ 1,076
Nominal current ² 4.5 A

PCB termination modules – 10 contacts

Operating voltage ¹ 320 V
Test voltage ¹ 1,320 V AC
Nominal current ² 4.5 A

PCB termination modules – 6 contacts

Operating voltage ¹ 500 V
Test voltage ¹ 1,730 V AC
Nominal current ² 8 A

PCB termination modules – 5 contacts

Operating voltage ¹ 555 V
Test voltage ¹ 1,959 V AC
Nominal current ² 16 A

PE module – 1 contact

Conduct cross-section 10 / 16 / 25 / 35 mm²

High‐voltage – 2 contacts

Operating voltage ¹ 4,000 V
Test voltage ¹ 7,198 V AC
Nominal current ² 12.5 A for 1 mm²

High-current – 3 contacts

Operating voltage ¹ 3,260 V
Test voltage ¹ 7,514 V AC
Nominal current ² 39 A for 6 mm²

High‐current – 2 contacts for turned contacts with ODU LAMTAC®

Operating voltage ¹ 611 V
Test voltage ¹ 2,251 V AC
Nominal current ² 68 A for 16 mm²

High‐current – 2 contacts for turned contacts with ODU LAMTAC®

Operating voltage ¹ 537 V
Test voltage ¹ 1,844 V AC
Nominal current ² 105 A for 25 mm²

High‐current – 1 contact for turned contacts with ODU LAMTAC®

Operating voltage ¹ 2,700 V
Test voltage ¹ 6,388 V AC
Nominal current ² 155 A for 50 mm²

Coax – 4 contacts for 50 Ω coax contacts

Frequency range 0–2.8 GHz

Coax – 2 contacts for 50 Ω coax contacts

Frequency range 0–4 GHz

Coax – 2 contacts for 50 Ω coax contacts

SMA termination

Frequency range 0–12 GHz

Coax – 2 contacts for 75 Ω coax contacts

Frequency range 0–2.7 GHz

Compressed air / fluid / vacuum coupling – 2 contacts

Tube-∅ inner-∅: max. 4 mm
Tube-∅ outer-∅ Push-in: max. 6 mm

Compressed air / fluid / vacuum coupling – 2 contacts

Tube-∅ M5 max. 4 mm

Compressed air / fluid / vacuum coupling – 2 contacts

Tube-∅ M5 inside thread

Compressed air / fluid / vacuum coupling – 1 contact

Tube-∅ 16 mm

Shielded feedthrough / high‐speed connector – 2 to 14 contacts for 2 insert size 1

Suitable for all common bus systems CAT 5, USB  2.0 3, USB  3.2 Gen 1x1 3, FireWire® 3, Ethernet, SPE 1000BASE-T1 4

Mating cycles min. 10,000

Shielded feedthrough / high‐speed connector – 2 to 14 contacts for 1 insert size 1

Suitable for all common bus systems CAT 5, USB  2.0 3, USB  3.2 Gen 1x1 3, FireWire® 3, Ethernet, SPE 1000BASE‐T1 4

Mating cycles min. 10,000

Shielded feedthrough / high‐speed connector – 3 to 22 contacts for 1 insert size 2

Suitable for all common bus systems CAT 5, CAT 6A, USB® 3.2 Gen 1x2 3, Ethernet, HDMI® 2.0/2.1 3, DisplayPort® 2.0 3

Mating cycles min 10,000

Shielded feedthrough / high‐speed connector – 1 contact

10 gigabit Ethernet according to IEEE 802.3 an CAT 6A according to ANSI/TIA/EIA‐568‐C.2 CAT 6A according to ANSI/TIA‐568.2‐D

Mating cycles min 5,000

Combination module – 2 contacts (High‐speed & coax)

Selected inserts are suitable and qualified for data rates up to 5 Gbit/s. Suitable for CAT 5, USB 2.0 3, USB 3.2 Gen 1x1 3, FireWire® 3, Ethernet, SPE 1000BASE‐T1 4

Coax 50 Ω/4 GHz or 75 Ω/2.2 GHz

Combination module – 2 contacts (High‐speed & compressed air)

Selected inserts are suitable and qualified for data rates up to 5 Gbit/s. Suitable for CAT 5, USB 2.0 3, USB 3.2 Gen 1x1 3, FireWire® 3, Ethernet, SPE 1000BASE‐T1 4

Compressed air 12 bar

Fiber optic – 4 contacts for fiber optic only pre‐assembled (Physical Contact)

Max. insertion loss ≤ 0.5 dB
Single mode 9 / 125 μm
Multi mode 50 / 125 μm

Fiber optic – 4 contacts for fiber optic only pre‐assembled (Expanded Beam)

Max. insertion loss ≤ 1.5 dB
Multi mode 50 / 125 μm

Fiber optic – 5 contacts for fiber optic also pre-assembled (POF)

Max. insertion loss ≤ 1,5 dB
Multi mode 980 / 1.000 μm

Blank modules – Used to fill incomplete frames

ODU-MAC® Black-Line Configurator

Use this configurator to request new modules for your existing ODU-MAC® interface.

1 According to IEC 61010-1:2010 (VDE 0411-1:2020-03), supply voltage from grid supply circuit (Cat.2).

2 Determined according to IEC 60512-5-2:2002 (DIN EN 60512-5-2:2003-01) at increased temperature 45 K.

3 The contact arrangement of an ODU data transmission connector differs from a standard data transmission connector due to the robust ODU specific design. However, the ODU design meets the electrical specifications of the respective standard data transmission protocol.

4 Single Pair Ethernet according to IEC 63171-6:2020 (IEEE 802.3bp).